[{"data":1,"prerenderedAt":473},["ShallowReactive",2],{"blog-eu-ecodesign-transformer-efficiency":3},{"_path":4,"_dir":5,"_draft":6,"_partial":6,"_locale":7,"title":8,"description":9,"date":10,"image":11,"author":12,"tags":13,"body":18,"_type":467,"_id":468,"_source":469,"_file":470,"_stem":471,"_extension":472},"\u002Fblog\u002Feu-ecodesign-transformer-efficiency","blog",false,"","EU Ecodesign Directive: New Transformer Efficiency Requirements for 2027","What manufacturers and buyers need to know about the upcoming EU Regulation 2019\u002F1783 Tier 2 efficiency requirements.","2026-02-05","\u002Fimages\u002Fblog\u002Feu-ecodesign.png","VoltBridge Engineering",[14,15,16,17],"regulation","EU","efficiency","Ecodesign",{"type":19,"children":20,"toc":448},"root",[21,29,36,41,67,72,78,85,190,196,201,207,213,256,262,280,286,292,310,316,321,364,370,414,420,425,443],{"type":22,"tag":23,"props":24,"children":25},"element","p",{},[26],{"type":27,"value":28},"text","The European Union's Ecodesign Directive continues to raise the bar for transformer efficiency. With Tier 2 requirements taking effect in July 2027, manufacturers and buyers must prepare for stricter loss limits. Here's what you need to know.",{"type":22,"tag":30,"props":31,"children":33},"h2",{"id":32},"background-eu-regulation-20191783",[34],{"type":27,"value":35},"Background: EU Regulation 2019\u002F1783",{"type":22,"tag":23,"props":37,"children":38},{},[39],{"type":27,"value":40},"The EU Ecodesign regulation for power transformers establishes minimum energy performance standards (MEPS) for transformers placed on the EU market:",{"type":22,"tag":42,"props":43,"children":44},"ul",{},[45,57],{"type":22,"tag":46,"props":47,"children":48},"li",{},[49,55],{"type":22,"tag":50,"props":51,"children":52},"strong",{},[53],{"type":27,"value":54},"Tier 1",{"type":27,"value":56}," (effective July 2021): Established baseline efficiency requirements",{"type":22,"tag":46,"props":58,"children":59},{},[60,65],{"type":22,"tag":50,"props":61,"children":62},{},[63],{"type":27,"value":64},"Tier 2",{"type":27,"value":66}," (effective July 2027): More demanding loss limits",{"type":22,"tag":23,"props":68,"children":69},{},[70],{"type":27,"value":71},"These regulations apply to transformers with a minimum power rating of 1 kVA used in 50Hz electricity transmission and distribution networks.",{"type":22,"tag":30,"props":73,"children":75},{"id":74},"tier-2-key-changes",[76],{"type":27,"value":77},"Tier 2 Key Changes",{"type":22,"tag":79,"props":80,"children":82},"h3",{"id":81},"for-oil-immersed-transformers-3150-kva",[83],{"type":27,"value":84},"For Oil-Immersed Transformers (≤ 3,150 kVA)",{"type":22,"tag":86,"props":87,"children":88},"table",{},[89,118],{"type":22,"tag":90,"props":91,"children":92},"thead",{},[93],{"type":22,"tag":94,"props":95,"children":96},"tr",{},[97,103,108,113],{"type":22,"tag":98,"props":99,"children":100},"th",{},[101],{"type":27,"value":102},"Capacity",{"type":22,"tag":98,"props":104,"children":105},{},[106],{"type":27,"value":107},"Tier 1 Max No-Load Loss",{"type":22,"tag":98,"props":109,"children":110},{},[111],{"type":27,"value":112},"Tier 2 Max No-Load Loss",{"type":22,"tag":98,"props":114,"children":115},{},[116],{"type":27,"value":117},"Reduction",{"type":22,"tag":119,"props":120,"children":121},"tbody",{},[122,146,168],{"type":22,"tag":94,"props":123,"children":124},{},[125,131,136,141],{"type":22,"tag":126,"props":127,"children":128},"td",{},[129],{"type":27,"value":130},"250 kVA",{"type":22,"tag":126,"props":132,"children":133},{},[134],{"type":27,"value":135},"425 W (A₀Ak)",{"type":22,"tag":126,"props":137,"children":138},{},[139],{"type":27,"value":140},"360 W",{"type":22,"tag":126,"props":142,"children":143},{},[144],{"type":27,"value":145},"-15%",{"type":22,"tag":94,"props":147,"children":148},{},[149,154,159,164],{"type":22,"tag":126,"props":150,"children":151},{},[152],{"type":27,"value":153},"630 kVA",{"type":22,"tag":126,"props":155,"children":156},{},[157],{"type":27,"value":158},"750 W (A₀Ak)",{"type":22,"tag":126,"props":160,"children":161},{},[162],{"type":27,"value":163},"640 W",{"type":22,"tag":126,"props":165,"children":166},{},[167],{"type":27,"value":145},{"type":22,"tag":94,"props":169,"children":170},{},[171,176,181,186],{"type":22,"tag":126,"props":172,"children":173},{},[174],{"type":27,"value":175},"1000 kVA",{"type":22,"tag":126,"props":177,"children":178},{},[179],{"type":27,"value":180},"1050 W (A₀Ak)",{"type":22,"tag":126,"props":182,"children":183},{},[184],{"type":27,"value":185},"890 W",{"type":22,"tag":126,"props":187,"children":188},{},[189],{"type":27,"value":145},{"type":22,"tag":79,"props":191,"children":193},{"id":192},"for-dry-type-transformers-3150-kva",[194],{"type":27,"value":195},"For Dry-Type Transformers (≤ 3,150 kVA)",{"type":22,"tag":23,"props":197,"children":198},{},[199],{"type":27,"value":200},"Tier 2 introduces even stricter requirements for dry-type units, particularly for no-load losses where amorphous core technology becomes increasingly attractive.",{"type":22,"tag":30,"props":202,"children":204},{"id":203},"impact-on-manufacturers",[205],{"type":27,"value":206},"Impact on Manufacturers",{"type":22,"tag":79,"props":208,"children":210},{"id":209},"design-changes-required",[211],{"type":27,"value":212},"Design Changes Required",{"type":22,"tag":42,"props":214,"children":215},{},[216,226,236,246],{"type":22,"tag":46,"props":217,"children":218},{},[219,224],{"type":22,"tag":50,"props":220,"children":221},{},[222],{"type":27,"value":223},"Core optimization",{"type":27,"value":225},": Higher-grade silicon steel (HiB or domain-refined)",{"type":22,"tag":46,"props":227,"children":228},{},[229,234],{"type":22,"tag":50,"props":230,"children":231},{},[232],{"type":27,"value":233},"Amorphous core adoption",{"type":27,"value":235},": Increasingly necessary for cost-effective compliance",{"type":22,"tag":46,"props":237,"children":238},{},[239,244],{"type":22,"tag":50,"props":240,"children":241},{},[242],{"type":27,"value":243},"Improved winding design",{"type":27,"value":245},": Reduced load losses through optimized conductor geometry",{"type":22,"tag":46,"props":247,"children":248},{},[249,254],{"type":22,"tag":50,"props":250,"children":251},{},[252],{"type":27,"value":253},"Better materials",{"type":27,"value":255},": Lower-loss core and winding materials",{"type":22,"tag":79,"props":257,"children":259},{"id":258},"testing-and-certification",[260],{"type":27,"value":261},"Testing and Certification",{"type":22,"tag":42,"props":263,"children":264},{},[265,270,275],{"type":22,"tag":46,"props":266,"children":267},{},[268],{"type":27,"value":269},"All transformers must be tested per EN 50588-1",{"type":22,"tag":46,"props":271,"children":272},{},[273],{"type":27,"value":274},"Third-party verification may be required",{"type":22,"tag":46,"props":276,"children":277},{},[278],{"type":27,"value":279},"Market surveillance authorities will conduct random checks",{"type":22,"tag":30,"props":281,"children":283},{"id":282},"impact-on-buyers",[284],{"type":27,"value":285},"Impact on Buyers",{"type":22,"tag":79,"props":287,"children":289},{"id":288},"for-eu-market-projects",[290],{"type":27,"value":291},"For EU-Market Projects",{"type":22,"tag":42,"props":293,"children":294},{},[295,300,305],{"type":22,"tag":46,"props":296,"children":297},{},[298],{"type":27,"value":299},"Specify compliance with EU 2019\u002F1783 Tier 2 in procurement documents",{"type":22,"tag":46,"props":301,"children":302},{},[303],{"type":27,"value":304},"Request loss-level guarantees with penalties for non-compliance",{"type":22,"tag":46,"props":306,"children":307},{},[308],{"type":27,"value":309},"Factor higher efficiency into lifecycle cost calculations",{"type":22,"tag":79,"props":311,"children":313},{"id":312},"for-non-eu-markets",[314],{"type":27,"value":315},"For Non-EU Markets",{"type":22,"tag":23,"props":317,"children":318},{},[319],{"type":27,"value":320},"Even if your project is outside the EU, Ecodesign standards are increasingly adopted as best practice:",{"type":22,"tag":42,"props":322,"children":323},{},[324,334,344,354],{"type":22,"tag":46,"props":325,"children":326},{},[327,332],{"type":22,"tag":50,"props":328,"children":329},{},[330],{"type":27,"value":331},"UK",{"type":27,"value":333},": Adopted EU standards post-Brexit",{"type":22,"tag":46,"props":335,"children":336},{},[337,342],{"type":22,"tag":50,"props":338,"children":339},{},[340],{"type":27,"value":341},"Turkey",{"type":27,"value":343},": Harmonized with EU requirements",{"type":22,"tag":46,"props":345,"children":346},{},[347,352],{"type":22,"tag":50,"props":348,"children":349},{},[350],{"type":27,"value":351},"Middle East",{"type":27,"value":353},": Some countries referencing EU loss levels",{"type":22,"tag":46,"props":355,"children":356},{},[357,362],{"type":22,"tag":50,"props":358,"children":359},{},[360],{"type":27,"value":361},"South America",{"type":27,"value":363},": Growing adoption of similar efficiency standards",{"type":22,"tag":30,"props":365,"children":367},{"id":366},"compliance-strategies",[368],{"type":27,"value":369},"Compliance Strategies",{"type":22,"tag":371,"props":372,"children":373},"ol",{},[374,384,394,404],{"type":22,"tag":46,"props":375,"children":376},{},[377,382],{"type":22,"tag":50,"props":378,"children":379},{},[380],{"type":27,"value":381},"Conventional silicon steel",{"type":27,"value":383},": Use highest-grade materials (domain-refined HiB)",{"type":22,"tag":46,"props":385,"children":386},{},[387,392],{"type":22,"tag":50,"props":388,"children":389},{},[390],{"type":27,"value":391},"Amorphous core",{"type":27,"value":393},": Easiest path to Tier 2 compliance for no-load losses",{"type":22,"tag":46,"props":395,"children":396},{},[397,402],{"type":22,"tag":50,"props":398,"children":399},{},[400],{"type":27,"value":401},"Hybrid designs",{"type":27,"value":403},": Amorphous core with optimized copper windings",{"type":22,"tag":46,"props":405,"children":406},{},[407,412],{"type":22,"tag":50,"props":408,"children":409},{},[410],{"type":27,"value":411},"Over-specification",{"type":27,"value":413},": Design to exceed Tier 2 for future-proofing",{"type":22,"tag":30,"props":415,"children":417},{"id":416},"voltbridge-eu-compliant-range",[418],{"type":27,"value":419},"VoltBridge EU-Compliant Range",{"type":22,"tag":23,"props":421,"children":422},{},[423],{"type":27,"value":424},"VoltBridge already manufactures transformers compliant with EU Ecodesign Tier 2:",{"type":22,"tag":42,"props":426,"children":427},{},[428,433,438],{"type":22,"tag":46,"props":429,"children":430},{},[431],{"type":27,"value":432},"S13 series (ultra-low loss silicon steel)",{"type":22,"tag":46,"props":434,"children":435},{},[436],{"type":27,"value":437},"S(B)H15 series (amorphous core)",{"type":22,"tag":46,"props":439,"children":440},{},[441],{"type":27,"value":442},"All units supplied with EU Declaration of Conformity and EN 50588-1 test reports",{"type":22,"tag":23,"props":444,"children":445},{},[446],{"type":27,"value":447},"Contact us for a quotation specifying Tier 2 compliance.",{"title":7,"searchDepth":449,"depth":449,"links":450},2,[451,452,457,461,465,466],{"id":32,"depth":449,"text":35},{"id":74,"depth":449,"text":77,"children":453},[454,456],{"id":81,"depth":455,"text":84},3,{"id":192,"depth":455,"text":195},{"id":203,"depth":449,"text":206,"children":458},[459,460],{"id":209,"depth":455,"text":212},{"id":258,"depth":455,"text":261},{"id":282,"depth":449,"text":285,"children":462},[463,464],{"id":288,"depth":455,"text":291},{"id":312,"depth":455,"text":315},{"id":366,"depth":449,"text":369},{"id":416,"depth":449,"text":419},"markdown","content:blog:eu-ecodesign-transformer-efficiency.md","content","blog\u002Feu-ecodesign-transformer-efficiency.md","blog\u002Feu-ecodesign-transformer-efficiency","md",1774678219744]