[{"data":1,"prerenderedAt":163},["ShallowReactive",2],{"product-switchgear":3},{"_path":4,"_dir":5,"_draft":6,"_partial":6,"_locale":7,"title":8,"description":9,"category":10,"image":11,"badge":7,"order":12,"quickSpecs":13,"specs":18,"body":32,"_type":157,"_id":158,"_source":159,"_file":160,"_stem":161,"_extension":162},"\u002Fproducts\u002Fswitchgear","products",false,"","KYN28A \u002F KYN61 HV Metal-Clad Switchgear","Indoor metal-clad withdrawable high-voltage switchgear for reliable power switching, protection, and control. Multiple voltage classes from 12kV to 40.5kV with rated current up to 4,000A.","Switchgear Equipment","\u002Fimages\u002Fswitchgear.png",5,[14,15,16,17],"Voltage: 12 – 40.5kV","Current: Up to 4,000A","Standards: IEC 62271","Type: Withdrawable",{"Rated Voltage":19,"Rated Current":20,"Short-circuit Breaking":21,"Short-time Withstand":22,"Circuit Breaker":23,"Operating Mechanism":24,"Panel Type":25,"Compartments":26,"Protection Rating":27,"Internal Arc":28,"Width per Panel":29,"Standards":30,"Certifications":31},"12kV \u002F 24kV \u002F 40.5kV","630A \u002F 1250A \u002F 2500A \u002F 3150A \u002F 4000A","Up to 50kA","Up to 50kA \u002F 4s","Vacuum circuit breaker (VCB)","Spring or magnetic actuator","Metal-clad, withdrawable","5 (busbar, circuit breaker, cable, CT, relay)","IP4X (between compartments)","IAC AFLR 31.5kA \u002F 1s","800mm \u002F 1000mm \u002F 1200mm","IEC 62271-200, GB\u002FT 3906","ISO 9001, CE, CNAS, KEMA type-tested",{"type":33,"children":34,"toc":151},"root",[35,44,50,56,112,118],{"type":36,"tag":37,"props":38,"children":40},"element","h2",{"id":39},"overview",[41],{"type":42,"value":43},"text","Overview",{"type":36,"tag":45,"props":46,"children":47},"p",{},[48],{"type":42,"value":49},"The KYN28A (12kV) and KYN61 (40.5kV) series metal-clad switchgear panels provide reliable high-voltage switching, protection, and control for power distribution systems. Designed with a withdrawable circuit breaker truck for easy maintenance and maximum safety.",{"type":36,"tag":37,"props":51,"children":53},{"id":52},"key-features",[54],{"type":42,"value":55},"Key Features",{"type":36,"tag":57,"props":58,"children":59},"ul",{},[60,72,82,92,102],{"type":36,"tag":61,"props":62,"children":63},"li",{},[64,70],{"type":36,"tag":65,"props":66,"children":67},"strong",{},[68],{"type":42,"value":69},"Withdrawable Design",{"type":42,"value":71},": Circuit breaker truck can be safely withdrawn for maintenance without de-energizing the entire switchgear",{"type":36,"tag":61,"props":73,"children":74},{},[75,80],{"type":36,"tag":65,"props":76,"children":77},{},[78],{"type":42,"value":79},"Five-Compartment Construction",{"type":42,"value":81},": Physical segregation of busbar, breaker, cable, CT, and relay compartments",{"type":36,"tag":61,"props":83,"children":84},{},[85,90],{"type":36,"tag":65,"props":86,"children":87},{},[88],{"type":42,"value":89},"Internal Arc Protection",{"type":42,"value":91},": IAC-rated design channels arc energy safely in the event of an internal fault",{"type":36,"tag":61,"props":93,"children":94},{},[95,100],{"type":36,"tag":65,"props":96,"children":97},{},[98],{"type":42,"value":99},"Flexible Configuration",{"type":42,"value":101},": Available as incoming, outgoing, bus-tie, metering, or capacitor compensation panels",{"type":36,"tag":61,"props":103,"children":104},{},[105,110],{"type":36,"tag":65,"props":106,"children":107},{},[108],{"type":42,"value":109},"Intelligent Control",{"type":42,"value":111},": Optional microprocessor-based relay protection and SCADA communication",{"type":36,"tag":37,"props":113,"children":115},{"id":114},"applications",[116],{"type":42,"value":117},"Applications",{"type":36,"tag":57,"props":119,"children":120},{},[121,126,131,136,141,146],{"type":36,"tag":61,"props":122,"children":123},{},[124],{"type":42,"value":125},"Power plant switchyards",{"type":36,"tag":61,"props":127,"children":128},{},[129],{"type":42,"value":130},"Industrial facility main distribution",{"type":36,"tag":61,"props":132,"children":133},{},[134],{"type":42,"value":135},"Utility substation (primary and secondary)",{"type":36,"tag":61,"props":137,"children":138},{},[139],{"type":42,"value":140},"Data center critical power switching",{"type":36,"tag":61,"props":142,"children":143},{},[144],{"type":42,"value":145},"Railway traction substations",{"type":36,"tag":61,"props":147,"children":148},{},[149],{"type":42,"value":150},"Renewable energy plant grid connection",{"title":7,"searchDepth":152,"depth":152,"links":153},2,[154,155,156],{"id":39,"depth":152,"text":43},{"id":52,"depth":152,"text":55},{"id":114,"depth":152,"text":117},"markdown","content:products:switchgear.md","content","products\u002Fswitchgear.md","products\u002Fswitchgear","md",1774678218482]